<?xml version="1.0"?>
<Articles JournalTitle="The Research in Heart Yield and Translational Medicine (RHYTHM)">
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>The Research in Heart Yield and Translational Medicine (RHYTHM)</JournalTitle>
      <Issn>3115-7270</Issn>
      <Volume>11</Volume>
      <Issue>2</Issue>
      <PubDate PubStatus="epublish">
        <Year>2016</Year>
        <Month>10</Month>
        <Day>10</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">One-Year Outcome of Everolimus-Eluting Stents versus Biolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention</title>
    <FirstPage>62</FirstPage>
    <LastPage>67</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName>Mohammad</FirstName>
        <LastName>Alidoosti</LastName>
        <affiliation locale="en_US">Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Vahideh</FirstName>
        <LastName>Sharifnia</LastName>
        <affiliation locale="en_US">Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Seyed Ebrahim</FirstName>
        <LastName>Kassaian</LastName>
        <affiliation locale="en_US">Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Alimohammad</FirstName>
        <LastName>Hajizeinali</LastName>
        <affiliation locale="en_US">Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Hamidreza</FirstName>
        <LastName>Poorhosseini</LastName>
        <affiliation locale="en_US">Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Mojtaba</FirstName>
        <LastName>Salarifar</LastName>
        <affiliation locale="en_US">Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Younes</FirstName>
        <LastName>Nozari</LastName>
        <affiliation locale="en_US">Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Elham</FirstName>
        <LastName>Hakki Kazazi</LastName>
        <affiliation locale="en_US">Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2016</Year>
        <Month>07</Month>
        <Day>04</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2016</Year>
        <Month>07</Month>
        <Day>04</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Background: The biolimus-eluting stent (BES), with a biodegradable polymer, has not been previously compared with the everolimus-eluting stent (EES), as a second-generation drug-eluting stent (DES).We sought to compare the 1-year outcome between the PROMUS&#x2122; stent (EES type) and the BioMatrix&#x2122; stent (BES type).
Methods: From March 2008 to September 2011, all patients treated with the PROMUS&#x2122; stent or the BioMatrix&#x2122; stent for coronary artery stenosis at Tehran Heart Center were enrolled. The primary end points were 1-year adverse events, comprising death, myocardial infarction, target vessel revascularization, and target lesion revascularization.&#xA0; The secondary end point was stent thrombosis. The Cox proportional hazard model was used to assess the adjusted association between the stent type and the follow-up outcome.
Results: From 949 patients (66.3% male, mean age =59.48 &#xB1; 10.46 y) with 1,018 treated lesions, 591 patients (630 lesions, 65.1% male, mean age = 59.24 &#xB1; 10.23 y) received the PROMUS&#x2122; stent and 358 patients (388 lesions, 68.2% male, mean age = 59.88 &#xB1; 10.83 y) were treated with the BioMatrix&#x2122; stent. Before adjustment, the rate of the primary end points was 3.2% and 3.4% in the EES and BES, respectively (p value = 0.925, HR (EES to BES) = 1.035, 95% CI: 0.50 to 2.13). The rate of stent thrombosis was 2% and 1.7% in the EES and BES, respectively (p value = 0.698). After adjustment on confounder variables, there was no statistically significant difference in major adverse cardiac events between the PROMUS&#x2122; stent and the BioMatrix&#x2122; stent (p value = 0.598, HR (EES to BES) = 0.817, 95% CI: 0.39 to 1.73).
Conclusion: At 1 year&#x2019;s follow-up, the BES and EES showed similar safety and efficacy rates in the patients undergoing percutaneous coronary intervention with a relatively low rate of adverse events in the 2 groups.&#xA0; &#xA0;&#xA0;</abstract>