<?xml version="1.0"?>
<Articles JournalTitle="The Research in Heart Yield and Translational Medicine (RHYTHM)">
  <Article>
    <Journal>
      <PublisherName>Tehran University of Medical Sciences</PublisherName>
      <JournalTitle>The Research in Heart Yield and Translational Medicine (RHYTHM)</JournalTitle>
      <Issn>3115-7270</Issn>
      <Volume>15</Volume>
      <Issue>1</Issue>
      <PubDate PubStatus="epublish">
        <Year>2020</Year>
        <Month>01</Month>
        <Day>29</Day>
      </PubDate>
    </Journal>
    <title locale="en_US">Coarctation Stenting in a Rare Case with Congenitally Corrected Transposition of the Great Arteries and the Bicuspid Aortic Valve</title>
    <FirstPage>27</FirstPage>
    <LastPage>30</LastPage>
    <AuthorList>
      <Author>
        <FirstName>Zahra</FirstName>
        <LastName>Khajali</LastName>
        <affiliation locale="en_US">Department of Cardiovascular Medicine, Shaheed Rajaei Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Majid</FirstName>
        <LastName>Maleki</LastName>
        <affiliation locale="en_US">Department of Cardiovascular Medicine, Shaheed Rajaei Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Bahram</FirstName>
        <LastName>Mohebbi</LastName>
        <affiliation locale="en_US">Department of Cardiovascular Medicine, Shaheed Rajaei Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran.</affiliation>
      </Author>
      <Author>
        <FirstName>Maryam</FirstName>
        <LastName>Aliramezany</LastName>
        <affiliation locale="en_US">Cardiovascular Research Center, Institute of Basic and Clinical Physiology Sciences, Kerman University of Medical Sciences, Kerman, Iran.</affiliation>
      </Author>
    </AuthorList>
    <History>
      <PubDate PubStatus="received">
        <Year>2018</Year>
        <Month>10</Month>
        <Day>19</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2019</Year>
        <Month>07</Month>
        <Day>06</Day>
      </PubDate>
    </History>
    <abstract locale="en_US">Congenitally corrected transposition of the great arteries (cc-TGA) is a rare congenital abnormality that occurs in 1 per 33000 live births. This abnormality comprises nearly 0.05% of all congenital heart defects, with at least 90% of cc-TGA patients having associated cardiac defects; some of these associated defects are, however, very rare. In this case report, we describe a 22-year-old man who referred to our hospital for the evaluation of hypertension and cardiac murmurs. Via echocardiography and catheterization, the patient was finally diagnosed with cc-TGA, bicuspid aortic valve, and coarctation of the aorta. He underwent successful percutaneous transarterial coarctoplasty without any complications at early and 6 months&#x2019; follow-up visits.</abstract>
    <web_url>https://rhythm.tums.ac.ir/index.php/jthc/article/view/971</web_url>
    <pdf_url>https://rhythm.tums.ac.ir/index.php/jthc/article/download/971/888</pdf_url>
  </Article>
</Articles>